Central Calgary
Calgary home cuts estimated energy demands by nearly 50 per cent.
Building Type | Single-Family 2+ Stories | Location | Calgary, AB |
Year Built | 1984 | Foundation Type | Concrete (Full Basement) |
Structure Type | Wood-Framed | Total Floor Area | 204.1m2 |
Climate Zone | 7a | Heating Degree Days | 5000 |
Retrofit Status | Complete | Year Completed | 2023 |
Retrofit Phasing | No | Geometry Changed | Yes |
Annual Energy Savings | 47.37% |
Project Team
- Solar Homes Inc. ( Builder )
Project Priorities
- Reduce Energy Consumption
- Increase Thermal Comfort
- Improve Indoor Air Quality
- Reduce GHG Emissions
- Repair and/or Renew Exterior
- Improve Home Value
Upgrades
- Exterior insulation/siding
- Heatpump
- Heatpump Hotwater
- Drain Water Heat Recovery
- Improved airtightness
- Insulate basement below grade
- Energy Recovery Ventilator
Project Description
In 2023, Solar Homes Inc. retrofitted this 1984 Calgary home, getting it to net-zero ready. By increasing the home’s airtightness, adding more insulation to the exterior walls and attic, and upgrading windows and mechanical system, the home’s estimated energy use dropped almost 50 per cent. The project even added an extension to the rear master bedroom.
The retrofit included the following improvements:
- Rear Master Bedroom Extension
- New Innotech Windows
- Electrical Service Upgrade 200A
- 6” Roxul with Corrugated Steel Siding on the exterior
- Sprayfoam attic to make it airtight and install R60 insulation
- 2.5 tonne Daikin heatpump
- 50 Gallon AO Smith Heatpump hotwater
- Drain Water Heat Recovery
- Disconnect Gas
- Reduce ACH50 from 3.50 to 0.93
- Space Heating Demand Reduced from 14.65kW to 6.44kW
- Insulate Basement 18” Below Grade (R20 added)
- Energy Recovery Ventilator
The home is now net-zero ready.